Dew point & condensation risk

Where water will condense in your room, and how far humidity jumps when the lights go off.

Units

Inputs

°C
%
°C

Wall, window, AC duct or leaf

°C

Result

Dew point

16.3°C

Surface margin

+1.7°C

Within 2 °C of dew point

RH after lights-off

74%

at 21 °C, same moisture
Warning: The surface is close to the dew point; small sensor errors or a cold night could put it under.
Warning: Night conditions (74% RH at 21 °C) fall inside the cited Botrytis high-risk zone (RH ≥ 70%, 17–24 °C).
How this is calculated

Dew point

γ = ln(RH/100) + 17.62T/(243.12+T); T_d = 243.12γ/(17.62−γ)

  • Magnus formula with Sonntag constants (17.62, 243.12 °C); accurate to about ±0.4 °C between −45 and 60 °C.

Condensation

margin = T_surface − T_dew; water condenses when the surface is at or below the dew point

  • The 2 °C 'close' buffer is a safety margin for sensor error (typically ±0.5 °C, ±2–3% RH), not a cited threshold.

Lights-off RH

RH₂ = RH₁ · SVP(T₁) / SVP(T₂) (same absolute humidity; capped at 100%)

  • Assumes no moisture is added or removed while the air cools; plants keep transpiring after lights-off, so real RH usually rises more.

Cited targets

From the genetics.guru grow library, in the units each source used. Grades: strong and moderate are peer-reviewed; community practice is untested.