Exhaust, heat load & circuit check

Size the exhaust fan, estimate the heat your equipment adds, and check the circuit against the 80% rule.

Units

Room & ducting

m
m
m
min
m

Exhaust

Recommended fan rating

272mΒ³/h

160 CFM

Room volume

3.2mΒ³

Before derating

190mΒ³/h

Fan ratings are at zero static pressure. Choose a fan whose curve still delivers this flow at your filter's pressure drop.

Equipment & circuit

W

Lights at wall draw, plus fans, dehumidifier, pumps

Heat & electrical load

Heat added

2,047BTU/h

0.17 tons of cooling Β· 0.6 kW

Current draw

5A

Continuous limit 12 A
0 A80% limit15 A
Within the 80% continuous-load limit for a 15 A breaker.
How this is calculated

Exhaust

CFM = room ftΒ³ Γ· minutes per air exchange Γ— derating (filter +25%, ~10% per bend, ~1% per ft of duct)

  • Derating factors are rules of thumb; check the fan's static-pressure curve.
  • 1 CFM = 1.699 mΒ³/h. Common practice is one full exchange every 1–3 minutes; this interval is a rule of thumb, not a cited target.

Heat load

BTU/h = W Γ— 3.412; 1 ton = 12,000 BTU/h

  • Add envelope/ambient gains and dehumidifier heat for sizing an AC.

Circuit

A = W / V; continuous loads ≀ 80% of breaker rating

  • Have a licensed electrician verify any new circuit.