VPD calculator

Leaf vapour-pressure deficit from air temperature, humidity and leaf-temperature offset, mapped against cited stage targets.

Units

Inputs

°C
%
°C

Negative = leaf cooler than air. Measure with an IR thermometer if you can.

Growth stage

Result

Leaf VPD

0.97kPa

Below the early–mid flower target of 1–1.5 kPa

Leaf temperature

24°C

Air VPD (no leaf offset)

1.35kPa

Dew point

17.6°C

RH for early–mid flower

44–59%

at this temperature
To move into the band at 26 °C, lower RH toward 59%, or raise the temperature.

Stage target evidence: Moderate

VPD across temperature and humidity

Outlined: Early–mid flower 1–1.5 kPa
Darker = higher VPD. Leaf offset -2 °C applied. Use arrow keys to explore; Enter or click to load a cell into the calculator.
Relative humidity %
90
80
70
60
50
40
30

Air temperature °C

26 °C, 60% RH: leaf VPD 0.97 kPa, below the early–mid flower band

How this is calculated

Leaf VPD

VPD = SVP(T_leaf) − RH/100 · SVP(T_air); SVP(T) = 0.61078·e^(17.27T/(T+237.3)) kPa

  • Leaf temperature = air temperature + offset. LED-lit leaves usually run cooler than air because LEDs emit little infrared; HPS leaves run closer to air temperature (community estimates, see cited targets).

RH for a target

RH = 100 · (SVP(T_leaf) − VPD) / SVP(T_air)

Dew point

γ = ln(RH/100) + 17.62T/(243.12+T); T_d = 243.12γ/(17.62−γ)

Cited targets

From the genetics.guru grow library, in the units each source used. Grades: strong and moderate are peer-reviewed; community practice is untested.